-
Same authors
-
Related articles
- Recommend this article
- Download citation
- Alert me if this article is cited
- Alert me if this article is corrected
|
||||||||||||||||||
Cahiers de l'ASEES 14 (2009) 27-37
DOI: 10.1051/asees/2009005
Traitement biologique des eaux usées textiles – Étude de cas : Station d’épuration des eaux usées textiles
Lamia Ayed, Jihane Cheriaa, Abdelkarim Cheref et Amina BakhroufLaboratoire d’Analyse, Traitement et Valorisation des Polluants de l’Environnement et des Produits, Faculté de Pharmacie, Rue Avicenne, 5000 Monastir, Tunisie
Publié en ligne le 18 décembre 2009
Résumé
En Tunisie, plusieurs usines de textiles ont comme activité principale le lavage des jeans, caractérisée par
un débit de charge de 50 L.kg-1 et COD de 94 g.kg-1. Le traitement de la pollution de l’environnement par des microorganismes
est une technologie prometteuse. Cette étude contribuera à comprendre le fonctionnement des boues activées
des eaux usées dans l’industrie textile. Pendant six mois, certains paramètres physico-chimiques sont telles que la surveillance
de la demande chimique en oxygène (DCO), demande biologique en oxygène (DBO) et de la couleur avec le
dénombrement des micro-organismes eucaryotes rotifères et bactériennes cultivables. Les souches bactériennes isolées
ont été identifiées biochimiquement par Api 20NE. Nos résultats montrent un nombre élevé de rotifères prédateurs pour
les bactéries dans les boues activées. Le rapport DBO/DCO calculé était faible (< 0,3). Le nombre élevé de rotifères est accompagné
d’une faible valeur de DBO/DCO. Une forte concentration en bacterie (cfu) a été observée lorsque le nombre de
rotifères baisse. Les souches bactériennes isolées à partir de boues activées ont été identifiées comme étant Pseudomonas
vesicularis, Pseudomonas maltophilia, Pseudomonas stutzeri, Pseudomonas cepacia, Achromobacter SrVD, Aeromonas
hydrophila et Sphingomonas paucimobilis.
Abstract - Biological treatment of textile wastewater – Case study: Textile wastewater plant
In Tunisia, several textile factories have as principal activity the washing out of jeans, characterized by a flow rate load
of 50 L.kg-1 and COD load of 94 g.kg-1. The treatment of environmental pollution by micro-organisms is a promising
technology. This study contribute to understand the fonctionment of activated sludge in industrial textile wastewater plant.
During six months, some physico-chemicals parameters were monitoring such as chemical oxygen demand (COD), biological
oxygen demand (BOD) and color with enumeration of eucaryotic micro-organism rotifer and cultivable bacterial.
Isolated bacterial strains were identified by biochemical Api20NE. Ours results shows a high number of rotifer predator
for bacteria in activated sludge. The BOD/COD calculated observed was low to < 0.3. The high number of rotifer accompanied
the low value of BOD/COD. The high average concentration of cfu was observed when the number of rotifer
decrease. The isolated bacterial strains from activated sludge were identified as Pseudomonas vesicularis, Pseudomonas
maltophilia, Pseudomonas stutzeri, Pseudomonas cepacia, Achromobacter SrVD and Aeromonas hydrophila.
Key words: Textile -- wastewater -- biodegradation -- dye
Mots clés : Textile -- eau usée -- biodégradation -- colorant
Correspondence: Lamia Ayed, alym712@yahoo.fr
© ASEES 2009
| What is OpenURL? |
- If your librarian has set up your subscription with an OpenURL resolver, OpenURL links appear automatically on the abstract pages.
- You can define your own OpenURL resolver with your EDPS Account. In this case your choice will be given priority over that of your library.
- You can use an add-on for your browser (Firefox or I.E.) to display OpenURL links on a page (see http://www.openly.com/openurlref/). You should disable this module if you wish to use the OpenURL server that you or your library have defined.




Document
BibSonomy
CiteUlike
Connotea
Del.icio.us
Digg
Facebook